Product image for ALLIED 9312-EW 28 CI 2G OW BOX EARS
Image thumbnail 0
Image thumbnail 1
Image thumbnail 2

Email

ALLIED 9312-EW 28 CI 2G OW BOX EARS

Manufacturer: Allied Moulded Products | Catalog # 9312-EW | Codale Part # 21781

$596.48/c (100 ea)
ea
Log in or register to view your price, purchase history, and more!
12 available

For Delivery

Not in local stock *
Check your local branch
28.0 Cu. In. Two gang electrical box for use with nonmeatllic sheathed cable - Machine tapped device holes, rigid hard box construction, no distortion with high temperatures, shatter resistant with low temperatures - Old work residential construction 2 HR fire resistive walls - Fiberglass reinforced polyester - thermoset box - Size: D=2 3/4", W=4 1/8", H=3 1/4" - Mount with Metal wing brackets/metal ears wall compression - Speed Klamps™ bulk packed

Technical Information

Applications
Old work residential construction 2 HR fire resistive walls
Cable Entry
Eight "no Tools" Knockouts With 4 Speed "K" Clamps
Insulation Type
Non-Conductive,Non-Metallic
Material
Polyester
Mounting Type
Metal Wing Brackets/metal Ears Wall Compression
Number of Gangs
2 Gang
Size
D=2 3/4", W=4 1/8", H=3 1/4"
Type
Two Gang Electrical Box For Use With Nonmetallic Sheathed Cable

Manufacturer Information

Brand
Allied Moulded Products, Inc.
Sub Brand
FIBERGLASSBOX

General Product Info

12-Digit UPC
085339291008
Color
Beige,Tan
Construction
Injection Molded
Product UPC
08533929100
Weight
0.4500 lb

Dimensions

Depth
2-3/4 Inch
Height
3 Inch
Width
4-1/8 in
Features
  • Machine tapped device holes, rigid hard box construction, no distortion with high temperatures, shatter resistant with low temperatures, Speed \"K\" Clamps bulk packed
Additional Materials
  • Galvanized steel brackets and plated carbon steel fasteners
  • Polyvinyl chloride clamps
Standards
  • ANSI / UL 514C: File No. E30594
Fire Resistance Classification in Wall Assemblies 2-Hours or less
  • Shall be separated by a horizontal distance of not less than 3 inches
  • Note: For more details please refer to the UL fire resistive directory and Allied Mouldeds CEYY.9379 (Outlet boxes and fittings classified for fire resistance)
Fire Test of Building Construction Materials
  • ANSI / UL 263: File No. CEYY.R9379 (Category / File No.)
  • Note: Products must also be certified to: ANSI / UL 514C
Application
  • Old work residential construction 2 HR fire resistive walls
Specifications
  • Wall Box



Compare